Home

Introduction

Introduction Interface

Support Sentence

NMEA0183

Support AIS Message

Message Usage IALA Msg6 IMO Metero Hydro

FAQ

Chaining AtoN Status Bits MMSI

IALA A-126 GLA message format

Parameter No. of bits Description MANDO
Message Id 6 Identifier for this message 6; always 6. 6
Repeat Indicator 2 Used by the repeater to indicate how many times a message has been repeated. 0 – 3; default = 0; 3 = do not repeat any more. 0
Source ID 30 MMSI number of source Unit Real AtoN station MMSI
Sequence Number 2 0 ~ 3 0
Destination ID 30 MMSI number of destination Unit. Configuration via AID,D.
Retransmit Flag 1 Retransmit Flag should be set upon retransmission:
0 = no retransmission = default
1 = retransmitted.
0
Spare 1 Not used. Should be zero. 0
DAC 10 Destination Area Code.
Default: 235 (UK & NI) or 250 (ROI)
235
FI 6 Function Identifier
Default: 10 for this GLA standard message
10
Analogue 10 0.05– 36V 0.05V step Supply voltage to AIS Unit
0 – Not Used
ADC1
Analogue 10 0.05– 36V 0.05V step Supply voltage to AIS Unit
0 – Not Used
ADC2
Analogue 10 0.05– 36V 0.05V step Supply voltage to AIS Unit
0 – Not Used
ADC3
AtoN Status Bits 5 4\ / 00 – no RACON installed; 01 – RACON not monitored
3 / \ 10 – RACON operational; 11 – RACON ERROR
2 \ / 00 – no light or no monitoring; 01 – Light ON
1 / \ 10 – Light OFF; 11 – Light ERROR
0 0 - Good Health, 1 - Alarm
Same as AIS message 21
Status Bits 8 bit[7] Digital Input Off/On
bit[6] Digital Input Off/On
bit[5] Digital Input Off/On
bit[4] Digital Input Off/On
bit[3] Digital Input Off/On
bit[2] Digital Input Off/On
bit[1] Digital Input Off/On
bit[0] Digital Input Off/On
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Digital Input
Off Position Satus 1 Off position or On position
0: On position
1: Off position
Same as AIS message 21
Spare 4 For future use. Should be zero. 0
Total of bits 136 Occupies 1 slot. -